generator cut outs

Discuss all things Model T related.
Forum rules
If you need help logging in, or have question about how something works, use the Support forum located here Support Forum
Complete set of Forum Rules Forum Rules

Topic author
sheppfour
Posts: 22
Joined: Sun Jan 06, 2019 10:38 pm
First Name: Chris
Last Name: Sheppard
* REQUIRED* Type and Year of Model Ts owned: 1919 TT TRUCK
Location: Chesapeake, VA

generator cut outs

Post by sheppfour » Sat Feb 02, 2019 11:27 pm

I tried to order a cut out last week and parts supplier said he was out and it may be 2 months before he gets any. Are they hard to find now ?

Where is everyone getting them ?

Thanks Chris

User avatar

Steve Jelf
Posts: 6493
Joined: Fri Jan 04, 2019 9:37 pm
First Name: Steve
Last Name: Jelf
* REQUIRED* Type and Year of Model Ts owned: 1923 touring and a few projects
Location: Parkerfield, Kansas
MTFCA Number: 16175
MTFCI Number: 14758
Board Member Since: 2007
Contact:

Re: generator cut outs

Post by Steve Jelf » Sat Feb 02, 2019 11:39 pm

My guess is that they all come from the same source, and that your best bet is to call all the Model T parts dealers to see if anybody still has one in stock.
The inevitable often happens.
1915 Runabout
1923 Touring


Topic author
sheppfour
Posts: 22
Joined: Sun Jan 06, 2019 10:38 pm
First Name: Chris
Last Name: Sheppard
* REQUIRED* Type and Year of Model Ts owned: 1919 TT TRUCK
Location: Chesapeake, VA

Re: generator cut outs

Post by sheppfour » Sat Feb 02, 2019 11:44 pm

Thank you. Enjoyed following your trip in the fall .

Thanks Chris

User avatar

Brian D
Posts: 178
Joined: Sun Jan 06, 2019 7:35 pm
First Name: Brian
Last Name: Dowell
* REQUIRED* Type and Year of Model Ts owned: 14 Touring 26 Runnabout 19 Canadian Touring
Location: St. Clair Michigan
MTFCA Number: 52162
MTFCI Number: 205

Re: generator cut outs

Post by Brian D » Sun Feb 03, 2019 8:18 pm

I've been waiting since October for a cut out!
Brian. :?
People who wonder if the glass is half empty or half full, miss the point. The glass is refillable.
Life is Good, be nice.


Bill Dizer
Posts: 279
Joined: Sun Jan 06, 2019 1:58 pm
First Name: Bill
Last Name: Dizer
* REQUIRED* Type and Year of Model Ts owned: 1925 coupe, 1927 depot hack
Location: Spencer, IN
MTFCA Number: 28610
MTFCA Life Member: YES
Board Member Since: 2014

Re: generator cut outs

Post by Bill Dizer » Sun Feb 03, 2019 9:03 pm

If you check at your local auto parts store for a ford 2N or 9N diode replacement for the cut out, other than possible mounting differences that really don't matter, it will work fine. Now those tractors may or were positive ground rather than the model t negative ground. All you do is check that the wire from the battery is hot, then attach it to one end of the diode, and, check the other side of the diode with a test light or volt meter. IF there is voltage there or the test light lights, you have it reversed! Switch the wire to the other side/end of the diode! Check again, the light or volt meter should indicate no voltage going through the diode. Then all you do is attach the wire from the generator output to the end of the diode, and it will charge, and shut off when the engine stops. If you can mount it to one of the cutout mounting screws, great, if not all you need to do is tape up the wires at both ends of the diode so they can't short out. There is no need to ground the diode in any way. It can hang in open air and work fine. All a diode does is prevent electricity from flowing in one direction, which is what the cutout does. A diode does not regulate voltage at all, it is Not a voltage regulator! Just as your cutout is not a regulator either. All either one does is prevent electricity from flowing back to the generator when it is not charging. Think of them as a one way valve-electricity can go through in one direction only. When the engine is running,and the generator is charging, the power it produces goes through the diode and on to the car/battery. When the generator is stopped or not charging, the electricity is blocked by the diode from getting back to the generator and trying to make it run as a motor, which runs the battery down, and can get the generator hot enough to ruin it.

A voltage regulator is a totally different unit. It does what it says, it regulates the output voltage and amperage, based on its sense of what the battery needs to remain charged. Not what a T had from new, but a good idea if you drive a lot especially at night, where you use more power.

User avatar

DaveD
Posts: 20
Joined: Wed Jan 16, 2019 10:35 am
First Name: Dave
Last Name: Dunn
* REQUIRED* Type and Year of Model Ts owned: 1923/24 Touring
Location: Lacey Wa
MTFCA Number: 50322

Re: generator cut outs

Post by DaveD » Sun Feb 03, 2019 9:07 pm

I put a diode in mine. Looks like OEM Ford on the outside. Easy install and inexpensive. https://www.modeltford.com/item/5055DIO.aspx


Philip
Posts: 238
Joined: Sun Jan 06, 2019 12:09 pm
First Name: Philip
Last Name: Thompson
* REQUIRED* Type and Year of Model Ts owned: 1924 touring
Location: Graham NC

Re: generator cut outs

Post by Philip » Mon Feb 04, 2019 8:01 am

i have the same problem with standard size rings. philip