I have always adjusted the float on my Holly NH to 15/64” from the machined flange to the flat top of the float. When I took my carb apart yesterday to make necessary adjustments and install new gaskets, I was surprised that the float measurement was 5/32”which is quite a bit less than what I set it at. How does the float measurement change over time without being touched? I’d like to know in case there is a way to prevent it. Jim Patrick
Holly NH Float adjustment
Forum rules
If you need help logging in, or have question about how something works, use the Support forum located here Support Forum
Complete set of Forum Rules Forum Rules
If you need help logging in, or have question about how something works, use the Support forum located here Support Forum
Complete set of Forum Rules Forum Rules
-
Topic author - Posts: 2434
- Joined: Sun Jan 06, 2019 10:55 pm
- First Name: James
- Last Name: Patrick
- * REQUIRED* Type and Year of Model Ts owned: 1926 Coupe
- Location: Bartow, FL
- Board Member Since: 2001
-
- Posts: 7237
- Joined: Fri Jan 04, 2019 9:37 pm
- First Name: Steve
- Last Name: Jelf
- * REQUIRED* Type and Year of Model Ts owned: 1923 touring and a few projects
- Location: Parkerfield, Kansas
- Board Member Since: 2007
- Contact:
Re: Holly NH Float adjustment
Is the upward force of the float enough to bend the brass tab pushing the needle enough to bend it over time? I can't say for sure, but I doubt it. Does the needle have a rubber tip? If so, maybe it's become compressed. Anyway, your ¹⁵⁄₆₄" is correct, though I suspect ¼" is close enough. I agree ⁵⁄₃₂" is too high.
The inevitable often happens.
1915 Runabout
1923 Touring
1915 Runabout
1923 Touring
-
Topic author - Posts: 2434
- Joined: Sun Jan 06, 2019 10:55 pm
- First Name: James
- Last Name: Patrick
- * REQUIRED* Type and Year of Model Ts owned: 1926 Coupe
- Location: Bartow, FL
- Board Member Since: 2001
Re: Holly NH Float adjustment
Thank you, Steve. The tip is rubber, but it is firm and sharp and does not appear to be compressed. When I filled the gas tank the carb did leak bad and I immediately shut off the valve so I figured the carb cup had to be overflowing because the float was 5/64” higher than it should have been allowing too much gas in before the valve closed. Thanks again. Jim Patrick
-
- Posts: 6523
- Joined: Sun Jan 06, 2019 11:18 am
- First Name: Scott
- Last Name: Conger
- * REQUIRED* Type and Year of Model Ts owned: 1919
- Location: not near anywhere, WY
- Board Member Since: 2005
Re: Holly NH Float adjustment
Jim
I have to wonder if perhaps you failed to reinstall a gasket under the float valve body when you changed gaskets, or the new gasket is a little thinner. The amount of extra travel you have on your float would equate to just about the thickness of that gasket back toward the hinge. Remember, the measurement is at the free end of the float, and the height of the float valve is immediately opposite the hinge/fulcrum. It would take only a very small change in the gasket thickness to appear as a large change at the free end.
I have to wonder if perhaps you failed to reinstall a gasket under the float valve body when you changed gaskets, or the new gasket is a little thinner. The amount of extra travel you have on your float would equate to just about the thickness of that gasket back toward the hinge. Remember, the measurement is at the free end of the float, and the height of the float valve is immediately opposite the hinge/fulcrum. It would take only a very small change in the gasket thickness to appear as a large change at the free end.
Scott Conger
Tyranny under the guise of law is still Tyranny
NH Full Flow Float Valves™
Obsolete carburetor parts manufactured
Tyranny under the guise of law is still Tyranny
NH Full Flow Float Valves™
Obsolete carburetor parts manufactured
-
- Posts: 7391
- Joined: Sun Feb 14, 2021 10:08 pm
- First Name: Pat
- Last Name: McNallen
- * REQUIRED* Type and Year of Model Ts owned: 1926-7 roadster
- Location: Graham, Texas
- Board Member Since: 2021
Re: Holly NH Float adjustment
In addition to the above, I would add that even a slight amount of wear at the float pivot or a very slight distortion of the needle or its seat could cause a significant change in the measured float level. Model T engines vibrate, and vibration can usually find a way to affect fine adjustments. Wear can also occur at the contact point between the float and the needle itself.