Modern dip stick install

Discuss all things Model T related.
Forum rules
If you need help logging in, or have question about how something works, use the Support forum located here Support Forum
Complete set of Forum Rules Forum Rules
User avatar

Topic author
JvanMaanen
Posts: 178
Joined: Sun Jan 06, 2019 6:25 pm
First Name: Jim
Last Name: Van Maanen
* REQUIRED* Type and Year of Model Ts owned: 15 Touring, 19 roadster, 22 Coupe, 08 SR
Location: Friday Harbor, WA
MTFCA Life Member: YES

Modern dip stick install

Post by JvanMaanen » Thu Jul 28, 2022 3:10 pm

I recently purchased a modern dipstick, Langs 3079DS that replaces the lower petcock. Installation instructions say a "slight" bend may be needed. It looks to me like it will require way more than a "slight" bend to get the tube to exit forward of the firewall under the hood. This is on a 19 roadster project. Can someone send me a picture or post one of one of these installed. Must be old age, but I just can't see how this can be routed.

Thanks Van

User avatar

FreighTer Jim
Posts: 1722
Joined: Sun Jan 06, 2019 10:50 am
First Name: James
Last Name: Jarzabek
Location: Dayton, OH
Board Member Since: 2008
Contact:

Modern dip stick install

Post by FreighTer Jim » Thu Jul 28, 2022 3:39 pm

I don’t know if this is what you bought ….

@ https://youtu.be/ih6n0guHqYA


FJ
Google “ Model T Transport “
MTFCA - MTFCI - MAFCA Member


Scott_Conger
Posts: 6523
Joined: Sun Jan 06, 2019 11:18 am
First Name: Scott
Last Name: Conger
* REQUIRED* Type and Year of Model Ts owned: 1919
Location: not near anywhere, WY
Board Member Since: 2005

Re: Modern dip stick install

Post by Scott_Conger » Thu Jul 28, 2022 3:50 pm

I would consider "slight bend" as a hopeful exaggeration. In reality it requires a sweeping bend, followed by a bit of a reversal of that bend to bring it back to a vertical insertion to the compression elbow.

You MUST KEEP BOTH BENDS IN THE SAME PLANE. When you are finished, lay it on a table and make sure it will lay flat on the table or the dipstick will never insert fully. It also helps to just put a tiny nip of a bend at the very tip of the dipstick itself so that the edge of the end does not "plow" along the copper tube during each insertion, but instead presents a blunt tip. This greatly improves insertion force to an easy slide like you'd expect.
Scott Conger

Tyranny under the guise of law is still Tyranny

NH Full Flow Float Valves™
Obsolete carburetor parts manufactured


Norman Kling
Posts: 4634
Joined: Tue Jan 08, 2019 1:39 pm
First Name: Norman
Last Name: Kling
Location: Alpine California

Re: Modern dip stick install

Post by Norman Kling » Thu Jul 28, 2022 4:10 pm

I looked at the first part of your U tube and then it cut off. I couldn't figure out how to see the rest of it. I am a computer nerd :roll:
Whatever you do, be sure it does not hang down or is so low something will knock it off or you will lose all your oil. And after you get everything set as you want it, open the top petcock and pour oil in until is just starts to drip out the petcock. Then pull the dipstick and see where it shows on the dipstick and mark that location as the "full" level. That level could vary in accordance with the bends and angle of the dipstick tube. Be sure to close the petcock.
Norm

User avatar

TRDxB2
Posts: 6262
Joined: Tue Jan 08, 2019 4:56 pm
First Name: Frank
Last Name: Brandi
* REQUIRED* Type and Year of Model Ts owned: Speedsters (1919 w 1926 upgrades), 1926 (Ricardo Head)
Location: Moline IL
Board Member Since: 2018

Re: Modern dip stick install

Post by TRDxB2 » Thu Jul 28, 2022 4:17 pm

Looking at what you purchased, copied some DIY examples posted in the forum that might help. Its hard to tell how long the tube is and where the handle would be accessible
Attachments
dip stick.png
The past is a great place and I don't want to erase it or to regret it, but I don't want to be its prisoner either.
Mick Jagger


Scott_Conger
Posts: 6523
Joined: Sun Jan 06, 2019 11:18 am
First Name: Scott
Last Name: Conger
* REQUIRED* Type and Year of Model Ts owned: 1919
Location: not near anywhere, WY
Board Member Since: 2005

Re: Modern dip stick install

Post by Scott_Conger » Thu Jul 28, 2022 4:54 pm

The "gentle bend" of the tube is a 90 degree arc over a wide area followed by a reverse curve.

you can clearly see the very short reverse, to go straight into the fitting, plus the little recurve on the dipstick to avoid scrubbing down the length of the tube, and without it, it is very difficult to get the dipstick to navigate the "reverse" portion of the curve and seat the final 1 1/2".

IMG_20220728_142915.jpg
IMG_20220728_143751.jpg
Last edited by Scott_Conger on Thu Jul 28, 2022 5:00 pm, edited 1 time in total.
Scott Conger

Tyranny under the guise of law is still Tyranny

NH Full Flow Float Valves™
Obsolete carburetor parts manufactured


DickC
Posts: 270
Joined: Mon Jan 07, 2019 7:51 am
First Name: Dick
Last Name: Cruickshank
* REQUIRED* Type and Year of Model Ts owned: 1912 Depot Hack, 1916 Touring
Location: Angier NC

Re: Modern dip stick install

Post by DickC » Thu Jul 28, 2022 4:58 pm

I have had this on two of my T's. After you finish bending and installing, don't expect the dip stick to go in easily. It takes a little persuasion but it is not too difficult to insert. I suggest that you drain the oil after installation and refill with the recommended quantity. Insert the dip stick and note the full position. Take a file and mark it for future reference.


speedytinc
Posts: 4729
Joined: Fri Feb 12, 2021 12:24 pm
First Name: john
Last Name: karvaly
* REQUIRED* Type and Year of Model Ts owned: 14/15 wide track roadster. 23 touring, 27 roadster pickup, 20ish rajo touring
Location: orange, ca
Board Member Since: 2020

Re: Modern dip stick install

Post by speedytinc » Thu Jul 28, 2022 5:04 pm

No concerns of a compression ring on copper tubing shearing from vibration? I am thinking it would be safer to convert to a flair fitting and or go to a steel tube.


Scott_Conger
Posts: 6523
Joined: Sun Jan 06, 2019 11:18 am
First Name: Scott
Last Name: Conger
* REQUIRED* Type and Year of Model Ts owned: 1919
Location: not near anywhere, WY
Board Member Since: 2005

Re: Modern dip stick install

Post by Scott_Conger » Thu Jul 28, 2022 5:32 pm

Dick

with the installation I described, my dipsticks slide in almost effortlessly. They are on 2 of my 4 T's and I've installed them on many others. Never a problem when following my own advice above.
Scott Conger

Tyranny under the guise of law is still Tyranny

NH Full Flow Float Valves™
Obsolete carburetor parts manufactured

User avatar

Topic author
JvanMaanen
Posts: 178
Joined: Sun Jan 06, 2019 6:25 pm
First Name: Jim
Last Name: Van Maanen
* REQUIRED* Type and Year of Model Ts owned: 15 Touring, 19 roadster, 22 Coupe, 08 SR
Location: Friday Harbor, WA
MTFCA Life Member: YES

Re: Modern dip stick install

Post by JvanMaanen » Thu Jul 28, 2022 5:42 pm

Scott just read your last post, so you answered my question. Can you post a pick of the bend over the engine mount and connection to the firewall. always nice to get the info from those that have been there and done that.

Thanks Van


Scott_Conger
Posts: 6523
Joined: Sun Jan 06, 2019 11:18 am
First Name: Scott
Last Name: Conger
* REQUIRED* Type and Year of Model Ts owned: 1919
Location: not near anywhere, WY
Board Member Since: 2005

Re: Modern dip stick install

Post by Scott_Conger » Thu Jul 28, 2022 5:56 pm

Van, for now I can say that it comes up at a slight angle "up" (very slight), and a slight angle "out" (again, very slight). The mounting tab generally must be drilled out a little to fit over the firewall bracket bolt. Even though it is angled "out" everything safely and easily clears the inside of the hood when closed.

The "up" bend is my decision to ensure any oily vapor wants to drain back and not out. The "out" angle is due to the fact that you MUST keep all bends in one plane and to come out of the hog's head, arc over the top, and secure with the tab that is supplied, the whole thing seems to be not parallel to the frame rail. Note: on my dad's Syverson hack, I had to make a LONGER mounting tab to clear the Syverson firewall, and that resulted in a nice parallel-to-the-frame installation. If the outward cant of the tube is objectionable, you can make a longer mounting tab like I did, loosen the compression nut, and swing the tube "inward" a little. Just know that the longer the tab, the more vibration you will experience of the tube...something I seek to avoid. On the hack, even with the longer mounting tab, it remained snug against the plywood cutout and experienced no extra vibration, since it was not entirely free-hanging. On a standard car, that choice might become problematic but would still take considerable time to manifest itself...regardless, I choose to not give it the opportunity.

again, I'll also stress the little bend at the tip of the dipstick, and also not mentioned previously, arcing the dipstick to match the curve of the tube allows for nearly effortless insertion (if the tube arc is a constant curve!) and the only resistance is a gentle one for the last 1 1/2". Without the recurve, it will dig in badly, show copper shaving on the tip, and risk getting a false "low" reading on it. It must seat relatively easily and consistently.

I'll try to get a photo tomorrow.
Scott Conger

Tyranny under the guise of law is still Tyranny

NH Full Flow Float Valves™
Obsolete carburetor parts manufactured

Post Reply Previous topicNext topic